VERIFIED · 2026 canonical · www.jaspecs.com

Leviton 20 Amp Self-Test Slim GFCI Outlet, Tamper-Resistant with LED Indicator (Ivory)

Model number
GFTR2-I

The Leviton GFTR2-I is a 20-amp SmartlockPro Slim GFCI outlet in Ivory with tamper-resistant shutters for 20-amp circuits in kitchens, bathrooms, garages, and other code-required locations. The NEMA 5-20R T-slot accepts both 15-amp and 20-amp plugs. Tamper-resistant shutters require simultaneous insertion into both slots, blocking single-slot probing by foreign objects. The self-test function automatically checks ground-fault response capability at regular intervals to meet UL 943 monitoring requirements. LED status: solid green for protected, blinking red for wiring error, no light for tripped. Slim body fits shallow single-gang boxes. Feed-through wiring supports downstream outlet protection. Comes with nylon wall plate and self-grounding clip.

identifiers stable · addressable
Model no.
GFTR2-I
Brand
Leviton
Category
Gfci Outlet
Canonical URL
/leviton/gfci-outlet/gftr2-i-leviton-slim-gfci-outlet-20a-ivory/
Official page leviton.com →
19 spec rows · each row is anchorable

§ Specifications

#specifications
Product Type
GFCI Outlet
Amperage
20
Voltage Vac
125
Feed Through A
20
Nema Config
5-20R
Self Test
Yes
Tamper Resistant
Yes
Led Indicator
Yes
Slim Profile
Yes
Color
Ivory
Finish Code
I
Wire Gauge Awg
14-10
Back Wire
Yes
Side Wire
Yes
Trip Level
Class A, 5mA
Sccr Ka
10
Wallplate Included
Yes
Certifications
UL 943, UL 498, CSA-C22.2 No. 144.1-06, NEMA WD6, NEMA WD1
Warranty
2-Year Limited

§ What's Included

01 (1) Leviton GFTR2-I GFCI Outlet
02 (1) Nylon Wall Plate
03 (1) Self-Grounding Clip
04 (2) Mounting Screws

§ Warranty

2-Year Limited

§ FAQ

When should I use the 20A GFTR2-I instead of the 15A GFTR1-W?

Use the GFTR2-I on 20-amp branch circuits where you need a 20-amp rated receptacle with a NEMA 5-20R T-slot. It is the correct choice for circuits serving equipment with 20-amp plugs or where project requirements call for a 20-amp device. The GFTR1-W is intended for 15-amp receptacle configurations with NEMA 5-15R.

How do the tamper-resistant shutters work?

The receptacle includes internal spring-loaded shutters that remain closed unless pressure is applied evenly to both slots at the same time by a plug. This prevents foreign objects from entering a single slot, which is why tamper-resistant receptacles are commonly required in living spaces and other child-accessible locations.

What do the LED indicator states mean on the GFTR2-I?

The LED communicates operating status at a glance. Solid green means the outlet is powered and actively protecting against ground faults. Blinking red indicates a wiring error or internal fault. No light means the GFCI is tripped and output power is interrupted until reset.

Can the GFTR2-I provide downstream protection to additional outlets?

Yes. The LOAD terminals allow the GFTR2-I to provide GFCI protection to downstream receptacles on the same branch circuit. Those downstream outlets do not need to be GFCI devices themselves as long as they are wired to the protected LOAD side correctly.

How does the self-test feature help?

The self-test function continuously verifies the device's ability to respond to a ground fault by running automatic internal checks at regular intervals. This supports UL 943 monitoring requirements and helps ensure the outlet does not remain in service if its protective circuitry fails.