Siemens 40 Amp Single Pole Type QP Circuit Breaker (Q140)

Model number
Q140

The Siemens Q140 is a 40-amp single-pole Type QP breaker built for heavy 120V dedicated circuits where a standard 15- or 20-amp breaker is not enough. Its plug-in QP construction fits directly into listed Siemens and Murray residential load centers, so replacement or expansion work stays simple when the panel calls for Type QP devices. A thermal-magnetic trip mechanism helps protect conductors from heat buildup during overloads while also clearing short circuits quickly. The 10 kAIC rating meets common residential fault-duty requirements, and Siemens backs the breaker with a Lifetime Limited warranty.

identifiers stable · addressable
Model no.
Q140
Brand
Siemens
Category
Circuit Breaker
Canonical URL
/siemens/circuit-breaker/q140-siemens-40a-single-pole-circuit-breaker/
Official page siemens.com →
14 spec rows · each row is anchorable

§ Specifications

#specifications
Product Type
Circuit Breaker
Poles
1
Amperage
40
Voltage Vac
120
Interrupt Rating Ka
10
Trip Type
Thermal-Magnetic
Afci Protection
No
Gfci Protection
No
Self Test
No
Plug On Neutral
No
Wire Gauge Awg
8-6
Compatible Panels
Siemens ES, EQ, PL, E, P, W, HW, HPW, G, HG, SGF, SN, XG, OG series; Murray panels
Certifications
UL 489
Warranty
Lifetime Limited

§ What's Included

01 (1) Siemens Q140 Circuit Breaker

§ Warranty

Lifetime Limited

§ FAQ

When would a homeowner use a 40-amp single-pole breaker?

A 40-amp single-pole breaker is generally used on specialized 120V circuits that draw substantial current and are engineered for that load. It is not common for ordinary receptacle or lighting branches. Before installing one, confirm the appliance rating and that the branch wiring is correctly sized, usually in the 8 AWG to 6 AWG range.

Does the Q140 install the same way as smaller Siemens QP breakers?

Yes, it uses the same Type QP plug-in mounting style as other Siemens residential breakers. The breaker seats onto the bus stab after engaging the panel rail, provided the load center is listed for Siemens QP devices. Always shut off the main breaker and remove the deadfront carefully before replacement.

Why does the breaker handle sit in the middle after it trips?

That middle position is the standard trip indication on Siemens residential breakers. It shows the breaker opened because of a fault rather than being manually switched off. To reset it, move the handle fully to OFF first and then back to ON.

Can I use the Q140 in any Siemens panel I own?

Not automatically. You need the panel labeling to list an approved Siemens Type QP breaker, and the circuit arrangement must support a 40-amp single-pole branch. The Q140 is compatible with Siemens ES, EQ, PL, E, P, W, HW, HPW, G, HG, SGF, SN, XG, and OG series panels and Murray load centers when the panel labeling allows it.