VERIFIED · 2026 canonical · www.jaspecs.com

Leviton 20 Amp Self-Test Slim GFCI Outlet, Non Tamper-Resistant with LED Indicator (White)

Model number
GFNT2-W

The Leviton GFNT2-W is a 20-amp SmartlockPro Slim GFCI outlet in White for kitchens, bathrooms, garages, and any 20-amp circuit. The self-test function runs automatic internal ground-fault checks to satisfy UL 943 monitoring requirements. LED provides real-time status: solid green for protected, blinking red for wiring error, no light for tripped state. Slim body fits shallow single-gang boxes. Feed-through wiring supports downstream outlet protection. Comes with nylon wall plate and self-grounding clip.

identifiers stable · addressable
Model no.
GFNT2-W
Brand
Leviton
Category
Gfci Outlet
Canonical URL
/leviton/gfci-outlet/gfnt2-w-leviton-slim-gfci-outlet-20a-white/
Official page leviton.com →
19 spec rows · each row is anchorable

§ Specifications

#specifications
Product Type
GFCI Outlet
Amperage
20
Voltage Vac
125
Feed Through A
20
Nema Config
5-20R
Self Test
Yes
Tamper Resistant
No
Led Indicator
Yes
Slim Profile
Yes
Color
White
Finish Code
W
Wire Gauge Awg
12-10
Back Wire
Yes
Side Wire
Yes
Trip Level
Class A, 5mA
Sccr Ka
10
Wallplate Included
Yes
Certifications
UL 943, UL 498, CSA-C22.2 No. 144.1-06, NEMA WD6, NEMA WD1
Warranty
2-Year Limited

§ What's Included

01 (1) Leviton GFNT2-W GFCI Outlet
02 (1) Nylon Wall Plate
03 (1) Self-Grounding Clip
04 (2) Mounting Screws

§ Warranty

2-Year Limited

§ FAQ

When should I use a 20-amp GFCI like the GFNT2-W instead of a 15-amp model?

Use the GFNT2-W on a 20-amp branch circuit where the wiring and breaker are rated for 20 amps and a 5-20R receptacle is required. A 15-amp GFCI is used on 15-amp circuits or where a 5-15R configuration is appropriate. Always match the receptacle, wire size, and breaker rating to the circuit design and local code requirements.

What does the LED indicator mean on the GFNT2-W?

The LED shows three main conditions: solid green means the outlet is powered and providing GFCI protection, blinking red indicates a wiring error or device fault, and no light means the device is tripped and power is off at the receptacle. If the LED blinks red after installation, check line and load wiring before attempting reset.

Can the GFNT2-W protect outlets downstream on the same circuit?

Yes. The GFNT2-W supports feed-through wiring so it can protect additional downstream receptacles connected to its LOAD terminals. This allows one upstream GFCI to provide ground-fault protection for multiple standard outlets farther along the branch circuit.

How does the self-test feature work?

The self-test circuit automatically performs internal checks to verify that ground-fault protection remains functional, satisfying UL 943 monitoring requirements. If the device detects that protection can no longer be provided, it is designed to trip and indicate a fault condition so the outlet can be replaced.

Will the GFNT2-W fit in a shallow electrical box?

Yes. The SmartlockPro Slim design is built with a reduced depth to fit more easily into shallow single-gang boxes compared with older bulkier GFCI devices. It also leaves more room for conductors and makes installation easier where box space is limited.