jaspecs
Bosch / Hvac / Climate 5000 Multi-Zone
Hvac Mini Split Heat Pump

Bosch Climate 5000 Multi-Zone

Bosch Climate 5000 Multi-Zone is a ductless heat pump outdoor unit family for serving two to five independently controlled rooms from one condenser. The BMS500-AAM series supports mixed wall-mount and ceiling cassette indoor units with total capacity from 18,000 to 48,000 BTU.

Refrigerant

R-454B current generation; R-410A legacy generation

Compressor Type

DC inverter variable-speed

Min Operating Temp Heating

-5 F for 100% capacity; operates to -22 F in Max Performance mode

Voltage

208-230V / 1Ph / 60HzV

Compatible Indoor Units

BMS500-AAU wall-mount heads, BMS500-AAU ceiling cassette heads

Individual Zone Capacity Btu

9000-24000 per indoor head

Model Comparison

4 models
Climate 5000 Multi-Zone
Specification 2-Zone 3-Zone 4-Zone 5-Zone
Model BMS500-AAM018-1CSXRABMS500-AAM027-1CSXRABMS500-AAM036-1CSXRBBMS500-AAM048-1CSXLC
capacity_btu 18000270003600048000
seer2 1921-222221.8
hspf2 9.69.89.810
max_zones 2345
legacy_r410a_model BMS500-AAM018-1CSXHCBMS500-AAM027-1CSXHBBMS500-AAM036-1CSXHBBMS500-AAM048-1CSXHC
outdoor_sound_dba 53535353
outdoor_dimensions 33.3 in W x 14.3 in D x 27.6 in H37.24 in W x 16.54 in D x 31.89 in H
outdoor_weight_lbs 106.9 lbs136.69-147.27 lbs

Shared Specifications

All models
refrigerant R-454B current generation; R-410A legacy generation
compressor_type DC inverter variable-speed
min_operating_temp_heating -5 F for 100% capacity; operates to -22 F in Max Performance mode
Voltage 208-230V / 1Ph / 60HzV
compatible_indoor_units BMS500-AAU wall-mount heads, BMS500-AAU ceiling cassette heads
individual_zone_capacity_btu 9000-24000 per indoor head
ENERGY STAR® Yes
contractor_only No
warranty compressor years: 10 · parts years: 10 · registration required: true · notes: Registered warranty requires registration within 30 days; unregistered coverage is 5 years. Field-installed parts are covered for 1 year.
notes 3-zone and 5-zone dimensions require engineering submittal verification. Total indoor head BTU should not exceed outdoor unit total BTU.